Abstract

AbstractIn Germany, structural fire design of masonry is carried out in a simplified way using tabulated minimum wall thicknesses depending on the loading level in fire. Against this background the procedure of structural fire design is shown briefly before two approaches for a more efficient verification of the fire resistance are explained. The first possibility is to determine the reduction factor for the design value of the actions in fire more precisely and thereby reduce the loading level. Secondly, a design methodology is presented which can be applied in case of masonry walls with low vertical load but a large load eccentricity at mid‐height of the wall. Finally, the verification of the fire resistance of masonry according to national technical approval is discussed with an explanation how to obtain the same loading level in fire if the design is based on DIN EN 1996‐3/NA as when it is based on DIN EN 1996‐1‐1/NA.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.