Abstract

The autoignition temperatures (AITs) of solvent mixture was important index for the safe handling of flammable liquids which constitute the solvent mixtures. This study measured the AITs and ignition delay time for n-propanol and formic acid system by using ASTM E659 apparatus. The AITs of n-Propanol and Formic acid which constituted binary system were 435 o C and 498 o C, respectively. The experimental AITs of n-propanol and formic acid system were a good agreement with the calculated AITs by the proposed equations with a few A.A.D. (average absolute deviation). And nPropanol and formic acid system was shown the minimum autoignition temperature behavior (MAITB).

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.