Abstract

This paper proposes the shear strength of stud connectors and behaviors of composite beams. The experimental work of the investigation reported herein is consisted of tests of 26 solid Push-out specimens, 24 Deck Push-out specimens and 15 composite beams. From this study, we could find out the following conclusions. 1. The shear strength of stud connectors in solid slab is also concerned with exponent function of cross-sectional areas of stud connectors. 2. The shear strength of stud connectors with Deck is concerned with Deck ribs ratio and stud connector length above ribs. 3. Effective moment of inertia and effective section modulus of partial composite beams are concerned with exponent function α=1/3 of composite degrees.

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.