Abstract

Recently, multilayer piping has been used widely. Multilayer piping has excellent durability and corrosion resistance. An effective means for quality maintenance of multilayer piping is the laser ultrasonic technique for checking the state of adhesion of the vinyl chloride layer and the steel layer of multilayer piping. The wave is refracted at the interface between the steel layer and the vinyl chloride layer based on the wave motion principle. The arrival time of the reflection wave was calculated and confirmed by measurements. If measurement of piping under high temperature becomes possible, the effectiveness of the non-destructive testing technology by the laser ultrasonic technique can be expected, enabling the production of higher reliability and quality of multilayer piping.

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.