Abstract

It is necessary to estimate the strength of masonry tunnels to maintain these tunnels and assess the influence of adjacent construction work. However, the methods of calculation have not been established yet. The authors performed S=1/2 arch part tests of the brickwork lining tunnel to investigate the mechanical properties of them. Then they simulated the tests using the Beam-Spring Model Analysis. As a result, they concluded the followings: 1) the strength characteristics of tunnel lining made of brick and joint material have been revealed, 2) the joint material between the inner and outer layers should be considered for this Beam-Spring Model Analysis, and 3) from the parameter study on the actual brickworks on the railway single-truck tunnel, the brickwork lining becomes very weak if there is a shortage of section or a background void.

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.