Abstract

For the renovation of the reinforced concrete boxed-wall building, a new opening would be constructed on multi-story wall frame, and local retrofit with post-installed adhesive anchors would be applied. In this study, evaluation method of tensile strength for a post-installed adhesive anchor embedded in wall plane was proposed. The non-fixed bond-tensile test of anchor specimens embedded in wall-slab specimen was conducted. The parameter of specimens are embedment length of anchors, wall thickness, and wall shapes. Tensile strength of the anchors could be evaluated due to previous formula with the assumption of the effect of local retrofit on bottom floor wall and floor slab.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.