The impact efficiency of air-borne fine particles on a bed particle has been studied, extending over wide range of the bed porosities. The conventional cell model seems to be effective in predicting the impact efficiency only when the bed porosity is high enough. Two bed structure models besides the conventional cell model were introduced and tested in this paper. A modified cell model in which fine particles enter a cell from a narrow area and at an accelerated velocity is useful when the bed porosity is more than 0.8. An impactor model which considers a bed as a round nozzle cascade impactor with a small aspect ratio was found to be effective when the bed porosity is less than 0.8.

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.