Abstract

Wind turbines on the coast of the Sea of Japan have been damaged by lightning in winter. This is due to the frequent occurrence of upward lightning from wind turbines in winter. Occurrence of upward lightning proves to be closely related to the temperature distribution at high altitudes. In this paper, the correlation between lightning hits of wind turbines and the height of the—10 °C layer is analyzed. When an upward lightning hits a wind turbine in winter, the height of the—10 °C layer is lower than 2000 m in most cases. Moreover, winter lightning is classified into two types, namely, the storm type and the inactive type, and it is found that the parameters of lightning currents observed by LLS differ depending on the type of lightning storm. © 2013 Wiley Periodicals, Inc. Electr Eng Jpn, 184(2): 44–50, 2013; Published online in Wiley Online Library (wileyonlinelibrary.com). DOI 10.1002/eej.22357

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.