Abstract

The measurement of the pollution and a countermeasure are important in the indoor air pollution by the chemical substance. The bake-out is one of the indoor air pollution countermeasures. The bake-out is a root-like countermeasure because the chemical substance contained in the building material is reduced. However, an examination about the effect of the bake-out isn't sufficient. A miniature bake-out device and emission quantity measurement device were made for this study. Then, the bake-out examination of the building material was done, and effect on a decline of the chemical substance was examined. It was confirmed that the emission rates of formaldehyde and TVOC decreased by the bake-out.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.