Abstract
We examined effects of excimer laser irradiation on blood. Five vials, each of which contained 3ml of blood, were exposed to 37.5mJ laser beam at 10 PPS in repetition rate for 10, 20, 30, 40, 50 seconds. One vial was left untreated as a control. No change in hematocrit value was observed after excimer laser irradiation. In contrast, the level of plasma free hemoglobin rose progressively with each increased duration of exposure. This study indicates that the lysis of erythrocytes does not occur in the laser-exposed cells. However, the damage to erythrocyte membrane took place as it was evidenced by progressive hemoglobin leakage into plasma.
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
More From: THE JOURNAL OF JAPAN SOCIETY FOR LASER SURGERY AND MEDICINE
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.