Abstract

The purpose of this study was to develop the device when they simulate the orthodontics and to simulate the effect of orthodontic force by temperature change. Using 6-axis force sensors, we developed the device which is possible to measure in up to three of teeth model at the same time. We calibrated the sensors which we used. As for the result, the error of forces and moments was maximum 2.06 %, and they were enough for the measurement. We measured forces and moments which occurred in the case of 2 types of different temperature change. The experimental results show that a small difference of temperature change causes big difference forces and moments.

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.