Abstract

In conventional Brillouin optical time domain reflectometry (BOTDR),mutual restraint between the spatial resolution and the width of spontaneous Brillouin scattering spectrum can not be avoided. To solve this problem, we ameliorated the approach using double ultra-short pulses as probe light. By detecting spectral envelope, the spatial resolution of BOTDR can be extracted. This method improves the spatial resolution of the BOTDR system and meanwhile avoids the influence of Brillouin gain spectrum broadening caused by narrowing pulse on measurement accuracy. The experimental results show that with this novel BOTDR system, the temperature measurement can be realized at a 0.5 m spatial resolution, and the large broadening of the spontaneous Brillouin scattering spectrum can be avoided.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.