Abstract
A dedicated synchrotron radiation source, SORTEC SOR ring, was built and started its operation in 1989. The vacuum performance that is responsible for the fast startup and long beam lifetime of the ring is evaluated by comparing the measured pressure and beam lifetime with a simulated pressure profile. When 30% is assumed as an effective pumping speed of nominal value, the outgassing yield of q0=5·10-13 (Torr·l/s/cm2) and effective photodesorption coefficient of ηeff= 1.5·10-6 (molec/ph) are obtained at an integrated beam dose of 250 (A·h) thereby demonstrating the cleanliness of our vacuum duct. By choosing the optimum operating point, in addition to the ion clearing, a beam lifetime of over 50 hrs at 200 mA beam current has been achieved after a year of machine commissionings.
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.