Abstract

We studied the long-term histological response of the human larynx to Gore-Tex implant and evaluated whether its biocompatibility. Retrospective histological study. We conducted medialization laryngoplasty with expanded polytetrafluoroethylene (ePTEE or Gore-Tex) in a patient with vocal-fold paralysis. A strip of Gore-Tex was folded several times and inserted into the pocket preserving the inner perichondrium through a thyroid cartilage window. The patient died 12 months later and we histologically analyzed the larynx. No evidence was seen of foreign body granuloma, migration, extrusion, or infection. A modest inflammatory response with a fibrous capsule was present around implants. We confirmed the infiltration of abundant collagen and numerous fibroblasts into the microporous implant structure. Histological examination results suggest that Gore-Tex implants are safe and biocompatible with the human larynx. A slight inflammatory response and infiltration of fibrous tissue into the implant itself demonstrated that Gore-Tex implants are immunologically well tolerated.

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.