Abstract
The concentrations of outdoor radon and its progeny were measured every three hours. An electrostatic collection method for radon and three count techniques for radon progeny were adopted to measure the concentrations continuously. The measurements carried out from Feburary 1991 to June 1992. The equilibrium equivalent thoron concentrations were also measured with a radon progeny monitor. The concentrations of radon and its progeny showed the same diurnal variation of a maximum in the morning and minimum in the evening. An averaged equilibrium factor (F) was 0.76 over the whole period. The ratio of radioactivity concentration, 222Rn: 218Po: 214Pb: 214Bi, was 1.00: 0.80: 0.78: 0.72 in outdoor air. In comparison with outdoor radon progeny, the outdoor concentration of thoron progeny was about 1/40 and human exposure was about one-tenth.
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.