Abstract
Gas foil bearings (GFBs) are expected to be used in a variety of turbomachinery such as turbocharger, compressor, air cycle machine. One of the main issues for implementing the GFB to the turbomachinery is wear due to rubbing between shaft and bearing. In order to reduce wear, it is important to precisely predict and lower the speed of lift-off. This paper presents measurement by the test rig for the evaluation of the lift-off speed. During the lift-off test, the drag torque of the GFB was measured and the lift-off was detected by its value. The static load applied to the GFB was varied from 2 N to 5.2 N and the influence of the load on the lift-off speed was estimated. The predicted lift-off speed corresponded with the measured value. It was found that pre-load of GFB is the main factor to determine the lift-off speed in the low static load condition, and contrary to the expectations, static load has little influence one the test results. Finally, this paper proposes the way to lower the lift-off speed.
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
More From: The Proceedings of the Dynamics & Design Conference
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.