Abstract

A new technique is developed to measure the electrical resistivity of conductor with a nonuniform temperature profile. The calculation method is derived from the temperature dependence of the electrical resistivity. The apparatus consists mainly of a high temperature environmental chamber, a power circuit of heating, a twenty-wavelength pyrometer, and a scanning pyrometer. After getting the resistance from the voltage drop of the specimen, the electrical resistivity in a wide temperature range of the specimen can be obtained by our calculation model. Preliminary results of the electrical resistivity of SRM 8424 over a wide temperature range (1000-3000 K) are presented. The perfect consistency between the measurement results and the nominal values justifies the validity of this technique.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.