Abstract

Authors designed the system connecting multi-story shear wall structure with short period and main structure constructed by rigid frame with long period located around it with hydraulic dampers, and applied this system to 45-story reinforced concrete building.By response analysis, we confirmed as follows, reducing response deformation of main structure by connecting these structures with viscous dampers, height distribution of maximum story shear of multi-story shear wall structure was shape like stairs increasing at stories laying dampers, energy absorbed by dampers occupied about 70% for input energy of earthquake.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.