Abstract

A semi-cylindrical bubble column of 50cm in diameter equipped with a simultaneous injection nozzle of gas and liquid was used as a cold model for s liquefier of the direct coal liquefaction.The gas holdup and the jet length in the column were affected significantly by the liquid flow. After the temperature of the feed fluids was suddenly changed, thermal image pictures were taken at regular time intervals, and the presence of the stagnant zone in the periphery was revealed.Unsteady-state thermal behavior in the bottom part of a liquefier was simulated on the basis of a heat balance model with lumped parameters such as heat exchange rate, heat capacity of the reactor wall, and heat evolution by the liquefaction reaction. The possibility of heat ac-cumulation in the stagnant zone was elucidated in cases where the heat capacity of the reactor wall was larger than that of the stagnant liquid and where the heat exchange rate between the jet and stagnant zone was small.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.