Abstract

The effect of cold-working on corrosion of AISI type 304(or 304L) stainless steels were investigated in high-purity water at 300°C under pressure of 87 kg/cm2. An X-ray diffractometer used to investigate the ferrite formation caused by cold-working. The corrosion results were compared with the corrosion in boiling 65% nitric acid and in boiling copper sulfate-sulfuric acid solution. The results are summarized as follows: (1) The degree of cold working does not seem to have a direct relation to the corrosion resistance of type 304 (or 304L) stainless steel in high temperature water and in boiling 65% nitric acid. (2) The ferrite produced by cold-working accelerates the corrosion in high temperature water. However, the ferrite does not seem to affect the corrosion resistance in boiling 65% nitric acid and in boiling copper sulfate-sulfuric acid solution. (3) The tensile strength measurement indicate the existence of the intergranular attack in high carbon specimens after the test in boiling copper sulfate-sulfuric acid solution. However, no evidence of intergranular attack is found in high temperature water.

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.