Abstract

This paper describes the method with high accuracy and high efficiency. The correction recording is done through the following procedures: (1) Recording graduations normally on the slave scale referring to the master scale. (2) Measuring the scale error. (3) Erasing. (4) Rerecording to cancel the scale error referring to the error data. The next two basic methods are executed to control recording pulses in the step (4): (a) Correction recording referring to the interpolated pulses of the masterscale. (b) Correction recording by the time conversion method. The following became clear: (1) The transcription with an accuracy of about 1'' can be done by the method (a). (2) The transcription with an accuracy of about 0.2'' can be done by the method (b) within the correction values of 1''. (3) Applying the 2 step correction recording method, which is combined method (a) with (b), to the masterscale, the scale with an accuracy of about 0.5'' has been recorded.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.