Abstract

This paper describes field experiments and evaluation on a snow melting system by using underground thermal energy in order to verify its energy saving performance. Firstly, experiments on a snow melting tank with a vertical earth heat exchanger which is 30m in depth were made and it was found that the heat extraction rate from the underground reached approximately 1.4kW. Secondly, an evaluation program on the snow melting system was developed, and the program was verified to give good predictions on the system performance.As a result of system simulations on a snow melting area, a length of the vertical earth heat exchanger and the tank volume, it was clarified that the energy consumption and CO2 emissions were greatly reduced comparing with conventional snow melting systems.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.