Abstract

The internal charge behaviour of insulation layers of printed circuit boards is discussed. Internal charges due to ion impurities can move under adc electric field, and the internal electric field is determined by the charges. The charge behaviour is strongly influenced by temperature and humidity. We have newly developed an in-situ space charge measurement system that can measure the space charge profiles in an environmental chamber at 85°C and 85%. Larger levels of internal charge were observed at higher humidity, and the electric fields near the electrodes were increased. The in-situ space charge measurement system should contribute to the study of ageing phenomena of insulation layers of PCBs.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.