Abstract

The load characteristics of induction motor manufactured by soft magnetic composite (SMC) are presented. We manufactured three kinds of induction motors experimentally. One is a conventional laminated iron core motor. The others are SMC motors. One of the SMC motor uses SMC only for stator, while the other SMC motor uses SMC for stator and rotor. The experimental comparisons of load characteristics and loss analysis are shown. As a result, the difference between the efficiency of the SMC motor and the conventional laminated motor is 4.6%, in spite of the permeability of SMC being 20% lower than the conventional electromagnetic steel.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.