Abstract

In the Higashiyokobori and Dotonbori rivers, water quality is controlled by inflowing outside non-polluted river water from upstream gate and outflowing inside water from downstream one. However, there is hypoxic water mass during high-temperature period. In the present study, field surveys, laboratory experiments, and numerical simulations were conducted to evaluate the water-quality improvement effect of exchanging water mass with outer rivers through the gates and to propose more effective methods. The results showed that main factor of hypoxia was DO consumption process in the waters and that more than 2.0 m3/s discharge through the gates is needed to maintain a good DO environment in summer.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.