Abstract

An improved configuration of SC coils, whose end coils are small, is studied to reduce their leakage flux. This paper examines the harmonic characteristics when the improved configuration of SC coils is applied to the 120-degree coil pitch ground coil. An adequate combination of length and mmf in the end coils can provide proper performance of harmonics and basis. © 2009 Wiley Periodicals, Inc. Electron Comm Jpn, 91(10): 20– 27, 2008; Published online in Wiley InterScience (www.interscience. wiley.com). DOI 10.1002/ecj.10163

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call