Abstract

The performance of a cyclone, of which the outlet pipe was eccentric to the cyclone axis, was investigated by experiments. The inserted length of outlet pipe, the eccentric distance and direction were changed. It was found that:1) When the eccentricity was above 10%, the pressure drops and the collection efficiency decreases.2) When the outlet pipe was not inserted into the cyclone chamber, the pressure drop and the collection efficiency decreased more than when it was inserted.