Abstract

Mass spectrometer for analyzing the exhaust gas was mounted at No. 2 BOF shop in NKK Fukuyama Works, and the level-up of refining under the computer control system using the exhaust gas information has been achieved. As the result, the continuous estimations of bath temperature, [O] and [C] etc. have been enabled, and the accuracy of end point control has been much improved. Moreover, rationalizing such as reductions of flux and steel making time has been achieved. Especially the productivity has been remarkably improved and the production amount has reached to 330 000 t month under one vessel operation with two vessels.

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.