Abstract
A wafer transportation apparatus with an advanced rotary magnetic coupling system for ultra-high vacuums has been developed. In this magnetic coupling system, the gap between the magnets and the yokes can be reduced to less than 1 mm, which enables a much larger coupling force than that of conventional systems.The apparatus has been evaluated. After a series of experiments, we found the following : 1) The rotational stiffness is more than 4.3 Nm/deg and the maximum rotational torque is more than 7.6 Nm.2) The positioning accuracy (±3δ) is ±0.048 deg in the circumferential direction and ±0.04 mm in extension and retraction.3) The outgassing rate from the wafer transportation apparatus is 6×10-8 Pam3/s after baking (120°C, 48 hr.).
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.