The atmosphere-forest heat exchange mechanism was investigated based on the measurement applying eddy correlation method at 3 heights above and 2 heights inside the canopy of a coniferous forest. Counter gradient or zero gradient sensible heat transport was observed inside the canopy. Cospectral analysis indicates that this counter gradient flux is caused by the high frequency eddies, suggesting that the penetrating cold temperature gusts are contributing to this phenomena. Large eddies are contributing to the co-gradient flux even in the canopy. A 2nd order turbulence closure model for a horizontally homogeneous field was applied to compare with the observation. For the wind from the valley, the observed temperature profiles and sensible heat flux agreed with the computation. However, for the wind from the ridge, the observed temperature field suggested the occurrence of drainage flows which are not expressed by the computation.
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.