Abstract

The water-proof test method of placing joint and cracking parts of concrete under high water pressure is proposed for evaluating the under ground concrete structure. The shape and size of concrete specimen, the high water pressure test apparatus and the leading crack apparatus are developed. The effects of the period of placing joint, the type of water stop material, the kind of waterproofing membrane with cracking at its behind on the water proof performance ware tested under the high pressure.The test results are shown clearly differences in type of material and kind of construction specification. The proposed test method can evaluate the water proof performance of under ground concrete structure under high water pressure.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.