Abstract

A simple distillation method using conduction type thermogravimetric meter (TG) on coal-derived liquids was investigated.It was found that under the following measuring conditions, this distillation method was good agreement with the standard distillation method (ASTM D-2892) which is used crude oil.1) Thermoelectromotive force difference in thermocouples between the heat buffer cover and sample container (bias voltage): 300μV2) Quantity of samples: 300-400mg It was also possible to measure the water content in coal-derived liquids with this method. The one-cycle measuring time required for the TG distillation method using a conduction type thermobalance was less than 90 minutes and this method was far quicker and easier than other methods. Furthermore, in terms of accuracy, it was considered that the method can com-pare well with the ASTM method.

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.