Abstract

In this paper, the following conclusions and summary can be made : 1) An energy absorption of concrete specimen with unit size of (10 × 10 × 10 cm) is examined from the experimental data under triaxial compression, and then a characteristic equation to evaluate energy absorption after failure of concrete is suggested. 2) An energy absorption of concrete specimen with different shapes and sizes is also considered from the experimental data. 3) A length of failure zone inside the concrete specimen with different shape ratio becomes longer with an increase in the confining pressure. 4) An energy absorption capacity per unit volume decreases with an increase in the size ratio of concrete specimen. 5) Applying the results obtained from items 1) through 4), concrete-filled tubular steel columns are analyzed, and analytical results are compared with the experimental data.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.