Abstract

In this paper, a grip amplified glove consists of pneumatic artificial rubber muscles (PARMs) which are covered with an exoskeleton structure is developed. A bi-rticular mechanism with a PARM that is suitable for bending finger is realized. The glove has totally 10 DOFs consist of four units. To achieve power-assist motion properly, a PI control, which is based on the pressure value from the balloon sensor, is applied. Synchronized actuation of the PARMs adds to the user's own movements provides power and support the grasping. As the balloon type sensors are used, electric circuits can be separated from the finger parts that have advantage in the use of hostile environment. To evaluate the validity of the glove, the skin surface electromyography (EMG) signals of muscles are measured during grasping. These results demonstrate that the eff ectiveness of the power amplified glove.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.