Abstract

The susceptibility to polythionic acid stress corrosion cracking of stabilized austenitic stainless steel weldments was investigated as a function of their sensitization measured by EPR method. The results showed that type 321 and 347 stainless steels became susceptible to stress corrosion cracking when the sensitization index in EPR test exceeded the value of 10%.In order to prevent the stress corrosion cracking of the weldment throughout the long time service of 105 hours or more, some countermeasures such as a stabilizing heat treatment should be provided to the type 321 and 347 weldments when they are used over 480°C and 430°C, respectively.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.