Abstract

In this study absolute myocardial perfusion was determined using a spin-labeling magnetic resonance imaging (MRI) technique at 2 Tesla. The technique was applied to 16 healthy volunteers at resting conditions, adenosine-induced stress, and oxygen breathing. Overall myocardial quantitative perfusion was determined as 2.3 +/- 0.8 mL/g/min (rest), 4.2 +/- 1.0 mL/g/min (adenosine), and 1.6 +/- 0.6 mL/g/min (oxygen), respectively. T1 of left ventricular blood pool decreased from 1709 +/- 101 ms (rest) to 1423 +/- 61 ms (oxygen), whereas T1 of right ventricular blood did not change significantly (1586 +/- 126 ms and 1558 +/- 150 ms). In conclusion, the presented technique for quantification of myocardial perfusion is an alternative to contrast agent-based methods. The spin labeling method is noninvasive and easily repeatable and it could therefore become an important tool to study changes in myocardial perfusion under different vasodynamic states.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.