Abstract

Myocardial blood flow under normal physiologic conditions remains relatively unaltered by coronary lesions with diameter stenosis of less than 70%. However, during cardiac arrest and cardiopulmonary resuscitation (CPR), autoregulation of coronary blood flow is compromised. We studied the effect of previously considered ‘trivial’ coronary stenoses of 10, 25 and 50% on distal myocardial perfusion in 39 swine undergoing CPR for cardiac arrest. Endocardial blood flow distal to the stenosis was significantly less than that proximal in all the different stenoses groups (P<0.05). A 50% diameter stenosis also compromised epicardial blood flow distal to the stenosis (P<0.05). This study suggests that any coronary lesion may compromise myocardial perfusion during CPR. Since the vast majority of cardiac arrest victims have coronary artery disease, careful attention to maximizing myocardial blood flow during CPR is needed.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.