Abstract

Objectives. This study sought to determine whether myocardial contrast echocardiography could be used to detect and quantitate collateral blood flow capable of limiting the effects of ischemia in an experimental model of coronary thrombosis and reperfusion.Background. Myocardial contrast echocardiography has been used to assess collateral blood flow in humans, but this technique has not been extensively validated in the experimental laboratory.Methods. Myocardial ischemia occurred after electrically induced left circumflex coronary artery thrombosis in a canine model. Ischemia was intensified by administration of vasodilators. Reperfusion was induced with recombinant tissue-type plasminogen activator. Myocardial perfusion was assessed with contrast echocardiography and radiolabeled microspheres. Infarct size was determined by histochemical staining methods. Myocardial samples were evaluated histologically.Results. The dogs were classified into two groups on the basis of contrast echocardiographic detection of perfusion in the ischemic region: those with (n = 13) and without collateral flow (n = 10). Collateral perfusion detected by contrast echocardiography paralleled changes detected by radiolabeled microspheres during thrombosis and vasodilator administration. A 91% agreement was observed between the two techniques in detecting collateral flow >0.3 mi/min per g (p < 0.0001). Collateral perfusion correlated directly with radial shortening fractions of the ischemic myocardium (p < 0.01). Recovery of function after reperfusion was faster, infarct size was smaller (mean [±SD] 4 ± 1% vs. 11 ± 3%, p = 0.05), and histopathologic injury was less in dogs with than without collateral flow, respectively (p < 0.05).Conclusions. Myocardial contrast echocardiography can identify physiologically significant collateral vessels capable of limiting the degree of ischemic damage during coronary thrombosis. The magnitude of collateral flow and the change in flow induced by vasodilators can be assessed and compares favorably with the microsphere standard.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.