Abstract

A highly sensitive spectral surface plasmon resonance (SPR) based fiber-optic sensor is proposed to diagnose the colorectal cancer that develops in the colon or rectal of intestine. Proposed sensor consists of transition metal carbides known as MXenes having chemical formula Ti <sub xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink">3</sub> C <sub xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink">2</sub> <inline-formula xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink"> <tex-math notation="LaTeX">$\text{T}_{X}$ </tex-math></inline-formula> based layered materials. The high sensitivity of fiber-optic sensor is attributed to high intercalation capacity, large surface area of 93.6 m <sup xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink">2</sup> g <sup xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink">−1</sup> , hydrophilic nature, biocompatibility, good thermal stability and high electrical conductivity of two-dimensional (2D) MXenes. The performance of sensor is analyzed under wavelength interrogation method in the wavelength range of 400 nm to 1000 nm. The dependence of angular characteristics of a multimode fiber-based sensor is investigated theoretically by optimizing the resonance curves to obtain the maximum sensitivity (S) and Figure of merit (FOM). The potential of two most popular plasmonic metals gold (Au) and silver (Ag) is demonstrated to compare the performance of the sensor. The sensor design is able to differentiate between normal and cancerous colorectal state due to their obtained in case of Au-Ti <sub xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink">3</sub> C <sub xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink">2</sub> based sensing probe is 6854.3 nm/RIU and 45.69 RIU <sup xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink">−1</sup> . The sensitivities of Ag, Ag-Ti <sub xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink">3</sub> C <sub xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink">2</sub> F <sub xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink">2</sub> , Ag-Ti <sub xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink">3</sub> C <sub xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink">2</sub> (OH) <sub xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink">2</sub> , Ag-Ti <sub xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink">3</sub> C <sub xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink">2</sub> O <sub xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink">2</sub> , Ag-Ti <sub xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink">3</sub> C <sub xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink">2</sub> based sensor are 6230.70 nm/RIU, 6308.46 nm/RIU, 6620.12 nm/RIU, 6386.31 nm/RIU and 10766.28 nm/RIU, respectively. The presence of MXenes in Ag based sensor enhances the sensitivity and FOM nearly 2 times compared to Au based sensor. Ultrahigh sensitivity of 10766.28 nm/RIU and FOM of 76.90 RIU <sup xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink">−1</sup> with low detection limit with Ag-Ti <sub xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink">3</sub> C <sub xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink">2</sub> based sensor is highest among the earlier reported fiber-optic SPR sensor for colorectal cancer detection.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call