Abstract

Accurate estimation of mutual inductance in wireless power transfer (WPT) system is a prerequisite for accurate identification of load parameters, which is critical in system constant output and efficiency tracking control. In this article, a general load decoupling method for WPT system considering soft-start process and battery initial voltage is proposed. Moreover, a double-sided <italic xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink">LCC</i> topology is used to explain how to calculate the boundary conditions of load decoupling. Based on the proposed load decoupling method, a mutual inductance identification method is proposed for WPT system with double-sided <italic xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink">LCC</i> topology. Within the frequency range recommended, the unique solution of mutual inductance can be obtained by solving high-ordered equivalent impedance equation. In this case, there is no need to discuss the situation for multiple solutions. Based on the WPT prototype, the effectiveness of the proposed load decoupling method is verified, and parameter sensitivity of the identification method is analyzed in detail. Finally, the proposed method is experimentally verified. Results show that high identification accuracy can be achieved even when the coils are misaligned. Compared with the existing identification methods, the proposed method does not need any additional switches and auxiliary circuits, which reduces the complexity and system cost effectively.

Full Text
Published version (Free)

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call