Despite the multi-linked architecture of the cervical spine, all previous studies that have made estimations of mechanical properties of the neck have considered the head–neck segment as a rigid link, with a fixed center of rotation at C7. The aim of this study was to consider the head–neck segment as a changeable geometry system for locating the resultant center of rotation and for calculating the musculo-tendinous stiffness by the quick-release method. Head kinematics during quick-releases was analyzed by recording the trajectory of surface markers. With an optimization procedure, the position of the resultant center of rotation of the head–neck segment was estimated. Thereafter, the angular displacement and acceleration of the head, together with the isometric torque developed by the cervical muscles were used to calculate the segment's stiffness. The results showed a consistent center of rotation and a significant increase of the musculo-tendinous stiffness with increasing torque.
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.