The aim of this study was to determine the characteristic of muscle crush injury at quantitative ultrasonographic elastography using supersonic shear imaging (SSI). Twenty-three New Zealand rabbits underwent crush injury to left hind leg caused by a special balloon cuff device. Conventional ultrasonography and SSI quantitative elastography were performed at both crushed and uncrushed regions of the left hind legs. Quantitative lesion elasticity was measured using the Young’s modulus (in kilopascals) at 0.5 h, 2 h, 6 h, 24 h and 72 h after the release of the crushing pressure. Compared with those from the uncrushed regions, both the maximum and mean elasticity values at these time points from the crushed regions were significantly higher (p < 0.001). A receiver operating characteristic (ROC) analysis was employed to assess diagnostic performance. ROC curves showed that extremity crush injury was diagnosed using elasticity value and the greater the elasticity value, the greater the diagnostic value. SSI provides quantitative elasticity measurements, thus, adding complementary information that potentially could help in crush injury characterization with conventional ultrasonography.

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.