Abstract

The compositions of commercially available solutions of short chain chlorinated paraffins (SCCP) and technical mixtures were determined by high resolution gas chromatography (HRGC) electron capture negative ionisation (ECNI) combined with low resolution mass spectrometry (LRMS). Differences and similarities in the relative distribution of congeners and homologues were investigated by cluster analysis. Samples could be separated into two groups/clusters with similar molecular mass, chlorination degree and congener pattern. With the exception of one sample, the use of CH4-ECNI-MS led to an overestimation of the chlorine content. Moreover, the influence of different SCCP mixtures on the quantification was studied. The results showed that small differences in the chlorine content could sometimes cause substantial systematic errors of up to 119% despite similar homologue and congener patterns. Errors of quantification corresponded to the deviations between response factors of sample and standard. As a consequence SCCPs should be quantified with a standard matching the overall response factor of the sample.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.