Abstract

This article presents the results of experimental studies of the stress–strain state of volumetric blocks based on the underlying frame structures. The aim of the research is to evaluate the stress–strain state and the nature of damage development as a result of an increase in the load up to a critical level. Based on the analysis of the nature of the damage, recommendations have been developed to strengthen the destruction zone. Data were collected on the redistribution of stresses and deformations, the formation of cracks and joint openings, the magnitude of horizontal displacements, and the failure mode of volumetric blocks and floor frames. Five full-scale volumetric blocks were tested under the loading of hydraulic jacks, differing in concrete type, reinforcement, presence of doors, and dimensions of the stylobate beams. When the volumetric modules were supported by a frame floor the results revealed that the maximum destructive load of 10,462 kN was observed in the first specimen; the horizontal displacements of the walls decreased by 13–18 mm, and there was a decrease in the crack opening width to 0.5 mm. The cracks decreased the strength of the walls, leading to a redistribution of the compressive stresses and their increase in the support zone. The most significant compressive strains in concrete in the corner parts of longitudinal walls were in the range of (600–620) × 10−6, and in the middle part of the walls, 370 × 10−6 were observed. Furthermore, the largest cracks caused significant horizontal displacements (deplanation) of the walls, which decreased the stiffness of the conjunction of longitudinal walls with the floor slab and created an additional eccentricity of the vertical force. Based on the findings, the correlation between the measured parameters of each specimen at all stages of vertical load increase is demonstrated and illustrated in graphs of the measured parameters. The importance of quantity compliance with the initial rigid connection between the longitudinal wall and ceiling plate has been estimated.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.