Abstract
MICs of fluconazole and amphotericin B were determined independently for 100 coded yeast isolates by each of six laboratories to determine reproducibility of results by using a colorimetric oxidation-reduction-based broth microdilution test. In addition, each site tested five quality control isolates on at least four different occasions during the study. Results agreed within a three-dilution range (mode +/- 1 log2 dilution) for 96.2% of fluconazole tests and 92.7% of amphotericin B tests. Agreement among tests with the quality control isolates was 99.4% with fluconazole and 98.6% with amphotericin B. These results indicate that the colorimetric microdilution method is reproducible among laboratories.
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.