Abstract

Detection of somatic low abundance mutations in early cancer development requires a discriminatory, specific, and high-throughput methodology. In this study we report specific, discriminatory detection of low abundance mutations through a novel combination of rolling circle amplification (Nat Genet 1998; 19:225–232) and PCR ligation detection reaction on a universal oligonucleotide microarray (J Mol Biol 1999; 292:251–262). After mutation-specific multiplex ligation and hybridization of 17 pairs of probes to a generic microarray, the ligated probes were visualized. The multiplex mutation-specific ligation is possible only because rolling circle amplification permits quantification of previously undetectable hybridization events conducive to the detection of a single mutation from within a pool of over 100 wild-type alleles. This system is readily adaptable to high-throughput automation using a robot such as the Biomek platform.