Abstract

Using atom beams to image the surface of samples in real space is an emerging technique that delivers unique contrast from delicate samples. Here, we explore the contrast that arises from multiple scattering of helium atoms, a specific process that plays an important role in forming topographic contrast in scanning helium microscopy (SHeM) images. A test sample consisting of a series of trenches of varying depths was prepared by ion beam milling. SHeM images of shallow trenches (depth/width < 1) exhibited the established contrast associated with masking of the illuminating atom beam. The size of the masks was used to estimate the trench depths and showed good agreement with the known values. In contrast, deep trenches (depth/width > 1) exhibited an enhanced intensity. The scattered helium signal was modeled analytically and simulated numerically using Monte Carlo ray tracing. Both approaches gave excellent agreement with the experimental data and confirmed that the enhancement was due to localization of scattered helium atoms due to multiple scattering. The results were used to interpret SHeM images of a bio-technologically relevant sample with a deep porous structure, highlighting the relevance of multiple scattering in SHeM image interpretation.

Highlights

  • Contrast in scanning helium microscopy has similarities with the origins of contrast in scanning electron microscopy, both of which involve rastering a focused or collimated beam across the sample and the collection of a fraction of the backscattered signal

  • We explore the contrast that arises from multiple scattering of helium atoms, a specific process that plays an important role in forming topographic contrast in scanning helium microscopy (SHeM) images

  • A test sample consisting of a series of trenches of varying depths was prepared by ion beam milling

Read more

Summary

Durham Research Online

The full-text may be used and/or reproduced, and given to third parties in any format or medium, without prior permission or charge, for personal research or study, educational, or not-for-prot purposes provided that:. A full bibliographic reference is made to the original source a link is made to the metadata record in DRO the full-text is not changed in any way The full-text must not be sold in any format or medium without the formal permission of the copyright holders. Please consult the full DRO policy for further details. Durham University Library, Stockton Road, Durham DH1 3LY, United Kingdom Tel : +44 (0)191 334 3042 | Fax : +44 (0)191 334 2971 https://dro.dur.ac.uk

Multiple scattering in scanning helium microscopy
Applied Physics Letters
Full Text
Published version (Free)

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call