Abstract
We present a measurement of multiple Coulomb scattering of 1 to 6 GeV/c electrons in thin (50–140 μm) silicon targets. The data were obtained with the EUDET telescope Aconite at DESY and are compared to parametrisations as used in the Geant4 software package. We find good agreement between data and simulation in the scattering distribution width but large deviations in the shape of the distribution. In order to achieve a better description of the shape, a new scattering model based on a Student's t distribution is developed and compared to the data.
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.