Abstract

A novel experiment to investigate single-surface multipactor on a dielectric surface was developed and tested. The compact apparatus consists of a small brass microwave cavity in a high vacuum system. The cavity is ∼15 cm in length with an outer diameter of ∼10 cm. A pulsed variable frequency microwave source at ∼2.4 GHz, 2 kW peak excites the TE111 mode with a strong electric field parallel to a dielectric plate (∼0.2 cm thickness) that is inserted at midlength of the cavity. The microwave pulses are monitored by calibrated microwave diodes. An electron probe measures electron current and provides temporal measurements of the multipactor electron current with respect to the microwave pulses. Phosphor on the dielectric surface is used to detect multipactor electrons by photoemission. The motivation of this experiment is to test recent theoretical calculations of single-surface multipactor on a dielectric.