Abstract

A power coupler is designed for the SC cavity. The multipacting analysis of the coupler is carried out by a code developed in house. The code calculates the enhanced counter function to evaluate the resonant trajectories. An emission model for secondary electrons is assumed and the emission energy and angle of secondary electrons are assigned by a Monte Carlo method. The multipacting bands are observed at the power levels of 0.3MW–1MW. DC bias voltages in the range of −8kV to −10kV are required to quench the multipacting completely.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.